Description

Specifications:
Model Active Membrane Area m2 Average Permeated Flow GPD (m3/d) Stable Rejection Rate (%) Minimum Rejection Rate (%)
ULP21-8040 33.9 11000 (41.6) 99.0 98.5
ULP12-8040 37.0 13200 (49.9) 98.0 97.5
ULP22-8040 37.0 12100 (45.7) 99.0 98.5
ULP32-8040 37.0 10500 (39.7) 99.5 99.0
ULP11-4040 8.4 2800 (10.6) 98.0 97.5
ULP21-4040 8.4 2400 (9.1) 99.0 98.5
ULP31-4040 8.4 1900 (7.2) 99.4 99.0
ULP11-4021 3.3 1000 (3.78) 98.0 97.5
ULP21-4021 3.3 950 (3.6) 99.0 98.5
ULP31-4021 3.3 850 (3.2) 99.4 99.0
ULP21-2521 1.3 300 (1.13) 99.0 98.5
ULP21-2540 2.6 750 (2.84) 99.0 98.5
Conversions
  • 1 US Gallon = 3.785 Liters
  • GPD x 3.785 / 24 hours = Liters per hour
Testing Conditions:
  • Testing Pressure: 150 psi (1.03Mpa)
  • Temperature of Testing Solution: 25 °C
  • Concentration of Testing Solution (NaCl): 1500ppm
  • pH Value of Testing Solution: 7.5
  • Recovery Rate of Single Membrane Element:
    • 15% (8040-size, 4040-size and 2540-size)
    • 8% (4021-size and 2521-size)
Operating Limits
  • Max. Working Pressure: 600psi (4.14Mpa)
  • Max. Feedwater Flow:
    • 7.5gpm (1 700l/h) (8040)
    • 1.6gpm (360l/h) (4040)
  • Max. Feedwater Temperature: 45°C
  • Max. Feedwater SDI: 5
  • Residual chlorine Concentration of Feedwater: <0.1ppm
  • pH Range of Feedwater during Continuous Operation: 3~10
  • pH Range of Feedwater during Chemical Cleaning: 2~12
  • Max. Pressure Drop of Single Membrane Element: 15psi (0.1Mpa)